产品概述:The online interactive UPS Otima II Tower has a rated voltage range of 800VA to 5KVA and provides server-grade full power protection against power failures, spi···
Online Interactive Uninterruptible Power System
Rated from 800VA to 5KVA, the Otima II Tower provides server-grade full power protection against power failures, spikes and surges in a small footprint with an output power factor of 0.9. This series is suitable for networking, telecom, server and mission critical applications.
main feature
●Pure sine wave
●Output power factor 0.9
●Adjustable power management socket
ECO (Efficiency Correction Optimizer) energy saving operation
●High-efficiency battery operation mode
Boost and Buck AVR for voltage stabilization
●Can provide a variety of communication ports
●3-section intelligent charging design
●Optional HID power supply USB port
Product Specifications
| MODEL | Otima II T 800 | Otima II T 1.1K | Otima II T 1.5K | Otima II T 2K | Otima II T 2.5K | Otima II T 3K | |
| capacity | 800VA / 720W | 1100VA / 990W | 1500VA / 1350W | 2000VA / 1800W | 2500VA / 2250W | 3000VA / 2700W | |
| ENTER | |||||||
| Rated voltage | 110/115/120/127VAC or 208/220/230/240VAC | ||||||
| acceptable voltage range | 81-152VAC or 162-290VAC | ||||||
| Frequency Range | 60/50 Hz (auto sensing) | ||||||
| OUTPUT | |||||||
| The output voltage | 110/115/120/127VAC or 208/220/230/240VAC | ||||||
| Frequency Range (Battery Mode) | 50 Hz or 60 Hz ± 1 Hz | ||||||
| transfer time | Typical 2-6 ms, 10ms max. | ||||||
| Waveform (Battery Mode) | Pure Sine Wave | ||||||
| Voltage Regulation (Voltage Mode) | ± 1.5% (before battery alarm) | ||||||
| Current crest ratio | 3:1 | ||||||
| Harmonic Distortion | 2% max @ 100% linear load, 5% max @ 100% non-linear load (before low battery alarm) | ||||||
| EFFICIENCY | |||||||
| battery mode | ≧ 88%, up to 90% @ nominal battery voltage | ≧89%, up to 91% @ nominal battery voltage for 110/115/120/127 VAC ≧91%, up to 92% @ nominal battery voltage for 208/220/230/240 VAC | |||||
| Buck and Boost Modes | 95% | ||||||
| ECO mode | 97% | ||||||
| BATTERY | |||||||
| Typical charging time | 4 hours recover to 90% capacity | ||||||
| Charger voltage | 27.4 VDC ± 1% | 54.8 VDC ± 1% | 82.1 VDC ± 1% | ||||
| Charge current (max) | 1.5A | ||||||
| Battery type and quantity | 12V/7Ah x 2 | 12V/9Ah x 2 | 12V/7Ah x 4 | 12V/9Ah x 4 | 12V/7Ah x 6 | 12V/9Ah x 6 | |
| PROTECT | |||||||
| full protection | Overload, discharge, and overcharge protection | ||||||
| INDEX | |||||||
| LCD Monitor | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery | ||||||
| ALARM | |||||||
| battery mode | Sounding every 10 seconds | ||||||
| low power | Sounding every 2 seconds | ||||||
| overload | Sounding every second | ||||||
| Fault | Continuously sounding | ||||||
| SURROUNDINGS | |||||||
| Working humidity | 0~90% RH @ 0- 40°C (non-condensing) | ||||||
| noise level | Less than 45dB | ||||||
| PHYSICS | |||||||
| Dimensions, D X W X H (mm) | 397x145x220 | 455 x 145 x 220 | 421 x 190 x 318 | ||||
| Net weight/kg | 11.7 | 12.1 | 17.2 | 19.7 | 26.6 | 29 | |
| MANAGE | |||||||
| Optional SNMP | Power management from SNMP manager and web browser | ||||||
| Smart RS-232/USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | ||||||
| Model | Otima II T 5K | |
| capacity | 5000VA / 4500W | |
| ENTER | ||
| Rated voltage | 208/220/230/240VAC | |
| acceptable voltage range | 162-290VAC | |
| Frequency Range | 60/50 Hz (auto sensing) | |
| OUTPUT | ||
| The output voltage | 208/220/230/240VAC | |
| Frequency Range (Battery Mode) | 50 Hz or 60 Hz ± 1 Hz | |
| transfer time | Typical 2-6 ms, 10ms max. | |
| Waveform (Battery Mode) | Pure Sine Wave | |
| Voltage Regulation (Voltage Mode) | ± 1.5% (before battery alarm) | |
| Current crest ratio | 3:1 | |
| Harmonic Distortion | 2% max @ 100% linear load, 5% max @ 100% non-linear load (before low battery alarm) | |
| EFFICIENCY | ||
| battery mode | ≧91%, up to 92% @ nominal battery voltage | |
| Buck and Boost Modes | 95% | |
| ECO mode | 97% | |
| BATTERY | ||
| Typical charging time | 4 hours recover to 90% capacity | |
| Charger voltage | 82.1 VDC ± 1% | |
| Charge current (max) | 1.5A | |
| Battery type and quantity | 12V/10Ah x 6 | |
| PROTECT | ||
| full protection | Overload, discharge, and overcharge protection | |
| INDEX | ||
| LCD Monitor | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery | |
| ALARM | ||
| battery mode | Sounding every 10 seconds | |
| low power | Sounding every 2 seconds | |
| overload | Sounding every second | |
| Fault | Continuously sounding | |
| SURROUNDINGS | ||
| Working humidity | 0~90% RH @ 0- 40°C (non-condensing) | |
| noise level | Less than 45dB | |
| PHYSICS | ||
| Dimensions, D X W X H (mm) | 421 x 190 x 318 | |
| Net weight/kg | 34.5 | |
| MANAGE | ||
| Optional SNMP | Power management from SNMP manager and web browser | |
| Smart RS-232/USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | |