产品概述:The CFL UPS is designed for lighting solutions. The sockets on the chassis can be used to directly insert energy-saving light bulbs with a full range of 360-deg···
The CFL UPS is designed for lighting solutions. The sockets on the chassis can be used to directly insert energy-saving light bulbs with a full range of 360-degree lighting. In addition, there are three sockets that can be used as lighting for connecting up to 3 CLF extension cords simultaneously. It is a perfect choice for emergency lighting, house lighting, camping, street vendors/street vendors or street lighting in remote villages.
Main Features
● 40W DC UPS
● Equipped with one energy saving light bulb socket
● 3 sets of DC energy saving light bulb power supply sockets
● Off charging mode
● Overload protection, battery mode and short circuit protection ●
3-color indicator lights
Product Specifications
MODEL | CFL UPS | |
capacity | 50VA/40W | |
ENTER | ||
Voltage | 230 VAC | |
voltage range | 100 VAC-300 VAC | |
OUTPUT | ||
Output voltage (AC mode) | 100 VDC-300 VDC | |
waveform | DC Output | |
Output Voltage (Battery Mode) | 160-230 VDC ± 10% | |
BATTERIES AND CHARGERS | ||
Battery type and quantity | 12V 7Ah x 1 | |
Typical charging time | 6 hours recover to 90% capacity | |
float voltage | 13.7 VDC ± 1.5% | |
recharging current | 1 A | |
Large capacity charging voltage | 14.5 VDC ± 1.5% | |
battery voltage | 12 VDC | |
INDEX | ||
Low battery (battery mode) | Yellow flashing every second | |
Normal battery voltage in battery mode | Yellow lighting | |
output short circuit | Red lighting | |
overcharging | Red LED staying on for one second and off for 4 seconds | |
overload | Red flashing rapidly every 0.5 second | |
Mains charging mode | Green flashing every 2 seconds | |
Line Mode Full Battery | Green lighting | |
PHYSICS | ||
Dimensions, D X W X H (mm) | 209 x 87 x 200 | |
Net weight (kg) | 2.7 | |
WORKING ENVIRONMENT | ||
Working humidity | 0~90% RH @ 0- 40°C (non-condensing) | |
noise level | Less than 40dB |